INT 13H 15H: Get Diskette Type or Check Hard Drive Installed
[AT]
Expects: AH 15H
DL drive: 00H thru 03H = diskette drive
80H or 81H = hard disk
──────────────────────────────────────────────────────────────────
Returns: AH 00H = not installed
01H = diskette drive: can't detect disk change
02H = diskette drive: CAN detect disk change
03H = it's a hard disk
else= BIOS disk error code if CF is set to CY
──────────────────────────────────────────────────────────────────
Info: This checks to see if a hard drive or diskette drive is
installed.
For diskette drives, this also finds if the drive is capable of
detecting change-line status (that is, will it be able to sense
when the drive door has been opened).
Notes: ■ On diskette drives which detect change-line status, you can use
INT 13H 16H to learn if the disk has been swapped.
See Also: DOS fn 440dH 68H (IOCTL sense media type)
INT 13H: BIOS Disk I/O
BIOS Data Area